Home / POCUS / Gastric / Volume calculator

Gastric volume calculator

Estimates gastric fluid volume from the antral cross-sectional area measured in the right lateral position. For non-pregnant adults.

Draft for clinical sign-off. Compiled 20 November 2026 by Dr Arun Mohanraj FRCA EDRA, Wrightington, Wigan and Leigh NHS Foundation Trust.

Measure in the right lateral position, between contractions, from outer wall to outer wall.25

How the figure is worked out

  • Area from two diameters. Area = anteroposterior diameter × craniocaudal diameter × π ÷ 4. Free tracing and the two-diameter method are equivalent.7
  • Volume. Volume (mL) = 27.0 + 14.6 × right lateral area (cm²) − 1.28 × age (years). The model was built from 108 patients whose gastric fluid was suctioned under gastroscopic vision.2
  • Threshold. Clear fluid above 1.5 mL/kg, or any solid, is the definition of a full stomach used in the diagnostic accuracy and cohort studies.68
  • Validity. The model applies to volumes from 0 to 500 mL in non-pregnant adults with a BMI below 40. It performed well in a separate study of severely obese subjects.211
  • Pregnancy and children. Use the population-specific studies; this calculator does not apply.1215

References

  1. Perlas A, Davis L, Khan M, et al. Gastric sonography in the fasted surgical patient: a prospective descriptive study. Anesth Analg 2011; 113: 93-7. https://doi.org/10.1213/ANE.0b013e31821b98c0
  2. Perlas A, Mitsakakis N, Liu L, et al. Validation of a mathematical model for ultrasound assessment of gastric volume by gastroscopic examination. Anesth Analg 2013; 116: 357-63. https://doi.org/10.1213/ANE.0b013e318274fc19
  3. Van de Putte P, Perlas A. Ultrasound assessment of gastric content and volume. Br J Anaesth 2014; 113: 12-22. https://doi.org/10.1093/bja/aeu151
  4. Perlas A, Van de Putte P, Van Houwe P, Chan VW. I-AIM framework for point-of-care gastric ultrasound. Br J Anaesth 2016; 116: 7-11. https://doi.org/10.1093/bja/aev113
  5. Perlas A, Arzola C, Van de Putte P. Point-of-care gastric ultrasound and aspiration risk assessment: a narrative review. Can J Anaesth 2018; 65: 437-48. https://doi.org/10.1007/s12630-017-1031-9
  6. Kruisselbrink R, Gharapetian A, Chaparro LE, et al. Diagnostic accuracy of point-of-care gastric ultrasound. Anesth Analg 2019; 128: 89-95. https://doi.org/10.1213/ANE.0000000000003372
  7. Kruisselbrink R, Arzola C, Endersby R, et al. Intra- and interrater reliability of ultrasound assessment of gastric volume. Anesthesiology 2014; 121: 46-51. https://doi.org/10.1097/ALN.0000000000000193
  8. Van de Putte P, Vernieuwe L, Jerjir A, et al. When fasted is not empty: a retrospective cohort study of gastric content in fasted surgical patients. Br J Anaesth 2017; 118: 363-71. https://doi.org/10.1093/bja/aew435
  9. Bouvet L, Desgranges FP, Aubergy C, et al. Prevalence and factors predictive of full stomach in elective and emergency surgical patients: a prospective cohort study. Br J Anaesth 2017; 118: 372-9. https://doi.org/10.1093/bja/aew462
  10. Bouvet L, Mazoit JX, Chassard D, et al. Clinical assessment of the ultrasonographic measurement of antral area for estimating preoperative gastric content and volume. Anesthesiology 2011; 114: 1086-92. https://doi.org/10.1097/ALN.0b013e31820dee48
  11. Kruisselbrink R, Arzola C, Jackson T, et al. Ultrasound assessment of gastric volume in severely obese individuals: a validation study. Br J Anaesth 2017; 118: 77-82. https://doi.org/10.1093/bja/aew400
  12. Arzola C, Perlas A, Siddiqui NT, et al. Gastric ultrasound in the third trimester of pregnancy: a randomised controlled trial to develop a predictive model of volume assessment. Anaesthesia 2018; 73: 295-303. https://doi.org/10.1111/anae.14131
  13. Sen S, Potnuru PP, Hernandez N, et al. Glucagon-like peptide-1 receptor agonist use and residual gastric content before anesthesia. JAMA Surg 2024; 159: 660-7. https://doi.org/10.1001/jamasurg.2024.0111
  14. El-Boghdadly K, Dhesi J, Fabb P, et al. Elective peri-operative management of adults taking glucagon-like peptide-1 receptor agonists, glucose-dependent insulinotropic peptide agonists and sodium-glucose cotransporter-2 inhibitors: a multidisciplinary consensus statement. Anaesthesia 2025.
  15. Spencer AO, Walker AM, Yeung AK, et al. Ultrasound assessment of gastric volume in the fasted pediatric patient undergoing upper gastrointestinal endoscopy. Paediatr Anaesth 2015; 25: 301-8. https://doi.org/10.1111/pan.12581