Home / POCUS / Gastric

Gastric POCUS

A two-minute bedside scan that shows whether the stomach is empty, holds clear fluid, or holds solid. It answers the question the fasting history cannot.

Draft for clinical sign-off. Compiled 20 November 2026 by Dr Arun Mohanraj FRCA EDRA, Wrightington, Wigan and Leigh NHS Foundation Trust.

Why scan

Fasted is not always empty

Elective

6.2% full

Of 538 fasted elective patients, 32 had a full stomach on ultrasound: 9 with solid and 23 with clear fluid above 1.5 mL/kg. Only six of the 32 had a recognised risk factor.8

Emergency

56% full

In 440 consecutive patients a full stomach was found in 56% of emergency cases and 5% of elective ones. Obesity, diabetes, emergency surgery and pre-operative opioids were independent predictors.9

Accuracy

Sensitivity 1.0

In a blinded study of 80 sessions with a 50% pre-test probability, gastric ultrasound detected a full stomach with a sensitivity of 1.0 and a specificity of 0.975.6

The framework

I-AIM: four steps

Indication, Acquisition, Interpretation, Medical decision-making.4

I

Indication

Fasting status unknown or unreliable, emergency surgery, delayed gastric emptying, or a patient taking a GLP-1 receptor agonist.45

A

Acquisition

Curved low-frequency probe in most adults. Scan the antrum supine or semi-recumbent, then in the right lateral position.5

I

Interpretation

Name the content: empty, clear fluid, or thick fluid and solid. If clear fluid, measure the volume.35

M

Medical decision

Combine the scan with the patient and the operation. The scan informs the plan; it does not make it.4

Acquisition

How to scan

  1. Use a curved low-frequency probe on an abdominal preset. A linear probe can be enough in thin adults and children.5
  2. Place the probe in the epigastrium in a sagittal plane, just below the xiphisternum, and slide from left to right.5
  3. Find the antrum: a hollow viscus lying between the left lobe of the liver in front and the pancreas behind, at the level of the aorta or the inferior vena cava.35
  4. Scan supine or semi-recumbent first, then turn the patient to the right lateral position. Fluid and solid move to the antrum under gravity, so the right lateral view is the more sensitive.15
  5. For volume, measure the antral cross-sectional area in the right lateral position, between contractions, including the full thickness of the wall.25
  6. Use either free tracing or two perpendicular diameters; the two methods agree, and trained anaesthetists reproduce the measurement closely.7

Interpretation

What the antrum looks like

ContentAppearanceMeaning
EmptyFlat or round with walls together, often described as a target or bull’s eye.Low risk
Clear fluidDistended, thin-walled, with dark (hypoechoic) content. Gas bubbles appear as bright dots soon after drinking.Measure the volume
Thick fluid, milkDistended with uniformly bright (hyperechoic) content.Full stomach
SolidEarly: a bright front wall with shadowing behind it, the frosted-glass pattern. Later: mixed, heterogeneous content.Full stomach

Appearances summarised from the systematic review and narrative review.35

Clear fluid

The three-point antral grade

Proposed from 200 fasted surgical patients, using only what is seen in the two positions.1

GradeSupineRight lateralPredicted volumePatients (of 200)
0EmptyEmptyNone86
1EmptyFluid seen16 ± 36 mL107
2Fluid seenFluid seen180 ± 83 mL7

From scan to decision

Solid, thick or particulate content of any amount, or clear fluid above 1.5 mL/kg, is treated as a full stomach. An empty antrum, or clear fluid at or below 1.5 mL/kg, is consistent with a fasted stomach.68

Special groups

Where the fasting history helps least

GLP-1 receptor agonists

56% against 19%

In 124 fasted patients, increased residual gastric content was found in 56% of those taking a once-weekly GLP-1 receptor agonist and 19% of controls.13 The UK multidisciplinary consensus advises continuing these drugs before surgery, with risk assessment and techniques to reduce aspiration risk.14

Severe obesity

Model holds

In 38 subjects with a BMI above 35, predicted and suctioned volumes agreed closely, with a mean difference of 35 mL.11

Third trimester

9.6 cm² cut-off

In 60 non-labouring women, an antral area of 9.6 cm² in the semi-recumbent right lateral position identified volumes of 1.5 mL/kg or more with a sensitivity of 80% and a specificity of 66.7%. The adult formula does not apply.12

Emergency surgery

Scan everyone

The authors of the 440-patient cohort concluded that gastric ultrasound should be performed in all emergency patients, and in elective patients with predictive factors.9

Area alone

340 mm² cut-off

A supine antral area of 340 mm² diagnosed an at-risk stomach, defined as solid or more than 0.8 mL/kg, with a sensitivity of 91% and a specificity of 71%.10

Children

Separate model

A paediatric model was derived from endoscopically suctioned volumes; the adult formula should not be used in children.15

Limits of the scan

  • The adult volume model was validated for 0 to 500 mL in non-pregnant adults with a BMI below 40.2
  • Studies excluded patients with altered gastric anatomy, such as previous gastric surgery.13
  • In one cohort the examination was inconclusive in 20 of 538 patients.8
  • The scan is used when the risk of aspiration is uncertain or unknown; it adds to clinical judgement and does not replace it.8
Research

Our systematic review

NORA² has registered a systematic review and meta-analysis of gastric ultrasound before anaesthesia and sedation on PROSPERO.

Videos

Scanning films

Scanning demonstrations and case examples are being added.

References

  1. Perlas A, Davis L, Khan M, et al. Gastric sonography in the fasted surgical patient: a prospective descriptive study. Anesth Analg 2011; 113: 93-7. https://doi.org/10.1213/ANE.0b013e31821b98c0
  2. Perlas A, Mitsakakis N, Liu L, et al. Validation of a mathematical model for ultrasound assessment of gastric volume by gastroscopic examination. Anesth Analg 2013; 116: 357-63. https://doi.org/10.1213/ANE.0b013e318274fc19
  3. Van de Putte P, Perlas A. Ultrasound assessment of gastric content and volume. Br J Anaesth 2014; 113: 12-22. https://doi.org/10.1093/bja/aeu151
  4. Perlas A, Van de Putte P, Van Houwe P, Chan VW. I-AIM framework for point-of-care gastric ultrasound. Br J Anaesth 2016; 116: 7-11. https://doi.org/10.1093/bja/aev113
  5. Perlas A, Arzola C, Van de Putte P. Point-of-care gastric ultrasound and aspiration risk assessment: a narrative review. Can J Anaesth 2018; 65: 437-48. https://doi.org/10.1007/s12630-017-1031-9
  6. Kruisselbrink R, Gharapetian A, Chaparro LE, et al. Diagnostic accuracy of point-of-care gastric ultrasound. Anesth Analg 2019; 128: 89-95. https://doi.org/10.1213/ANE.0000000000003372
  7. Kruisselbrink R, Arzola C, Endersby R, et al. Intra- and interrater reliability of ultrasound assessment of gastric volume. Anesthesiology 2014; 121: 46-51. https://doi.org/10.1097/ALN.0000000000000193
  8. Van de Putte P, Vernieuwe L, Jerjir A, et al. When fasted is not empty: a retrospective cohort study of gastric content in fasted surgical patients. Br J Anaesth 2017; 118: 363-71. https://doi.org/10.1093/bja/aew435
  9. Bouvet L, Desgranges FP, Aubergy C, et al. Prevalence and factors predictive of full stomach in elective and emergency surgical patients: a prospective cohort study. Br J Anaesth 2017; 118: 372-9. https://doi.org/10.1093/bja/aew462
  10. Bouvet L, Mazoit JX, Chassard D, et al. Clinical assessment of the ultrasonographic measurement of antral area for estimating preoperative gastric content and volume. Anesthesiology 2011; 114: 1086-92. https://doi.org/10.1097/ALN.0b013e31820dee48
  11. Kruisselbrink R, Arzola C, Jackson T, et al. Ultrasound assessment of gastric volume in severely obese individuals: a validation study. Br J Anaesth 2017; 118: 77-82. https://doi.org/10.1093/bja/aew400
  12. Arzola C, Perlas A, Siddiqui NT, et al. Gastric ultrasound in the third trimester of pregnancy: a randomised controlled trial to develop a predictive model of volume assessment. Anaesthesia 2018; 73: 295-303. https://doi.org/10.1111/anae.14131
  13. Sen S, Potnuru PP, Hernandez N, et al. Glucagon-like peptide-1 receptor agonist use and residual gastric content before anesthesia. JAMA Surg 2024; 159: 660-7. https://doi.org/10.1001/jamasurg.2024.0111
  14. El-Boghdadly K, Dhesi J, Fabb P, et al. Elective peri-operative management of adults taking glucagon-like peptide-1 receptor agonists, glucose-dependent insulinotropic peptide agonists and sodium-glucose cotransporter-2 inhibitors: a multidisciplinary consensus statement. Anaesthesia 2025.
  15. Spencer AO, Walker AM, Yeung AK, et al. Ultrasound assessment of gastric volume in the fasted pediatric patient undergoing upper gastrointestinal endoscopy. Paediatr Anaesth 2015; 25: 301-8. https://doi.org/10.1111/pan.12581